Description

 

VDL200

Input Voltage : @ULN=3x400 VAC (-15%+10%)
Digital Inputs : 8 Digital Input (NPN/PNP) and 1 Digital Enable
Relay Outputs : 4 Relay Outputs
Analog Inputs : 1 Piece Included
Encoder Card Included : Digital 5 VdcTTL / Absolute ENDAT
Input EMI Filter : Included
Output Filter : Included

 

Nominal output current in the operating temperature range of -10 ….+45 °C

Motor Current = Drive Current

Auto-tuning ability without turning the motor and disconnecting the load

Quite operation with no vibration at low speed due to high triggering frequency (switching frequency 10 kHz)

Brake release with feature of holding at zero-speed. Brake control function improved for lift machines

Overload 200% for 10 sec

Counter-weight control function

Selection of easy direction at first movement of rescue operation by means of car load detection function during last normal travel

Easy adjustment of high-comfort by using four-zone gain setting parameters

Improved comfort and control feature for high pole number motors with 300 Hz high motor speed

Turkish menu

Quick start-up for easy parameter setting

By using Gefran Keypad, driver settings can be recorded in 5 different memories and transferred to the other driver

 

  • Multispeed control
  • Short floor management
  • Emergency single-phase power supply for floor return with low energy optimization
  • Flexible ramp management
  • Integrated braking unit
  • Communication with control board via I/O
  • Management of TTL incremental digital encoders
  • Integrated EMI filter for versions (VDL200….-F)
  • 200% overload for 10 seconds
  • Conforms to UNI EN 81-1:1998 + A3:2009, article 9.11.3

 

 

Description

The VDL200 drive series is designed for low and medium rise geared applications in both open and closed loop with asynchronous motors.

High-performance control algorithms allow installation in sensorless configuration while maintaining the comfort level provided by highrange inverters.

Simple installation and configuration make the VDL200 ideal for modernizing the present systems as well as for the new installations.

 

 

Lift Functions

 Basic and advanced lift functions are incorporated in a single product, to ensure maximum comfort for all systems at all times

  • Speed Control: EFC (Elevator Floor Control) function: Separate function for independent management of short floors, landing zone, re-starting with lift not at floor and automatic deceleration point calculation
  • Lift sequence: Typical sequence of input/output signals used in lift engineering applications such as I/O management, braking, output contactor and door control.
  • Parameters in linear unit: Possibility of selecting different engineering units for the main movement parameters, rpm or m/s for speed, m/s2, m/s3 for car acceleration.<>/li
  • Lift mechanical parameters: Mechanical system parameters such as pulley diameter and speed ratio for converting system units and weights, system for calculating inertia and speed regulation for the desired response.
  • Ramp generation: Independent configuration of acceleration and deceleration ramp parameters and of the 4 jerk values for maximum travelling comfort in the lift car. Two independent S-shaped ramps, selectable via digital input with 4 independent jerk settings. Dedicated deceleration ramp corresponding to the stop command.